JSTJS-E高压介质损耗测试仪检验

 

仪器:  1%

 

检验数据:

电容

介损

 10kv

标准值

测量值

标准值

测量值



49.94pF

49.94pF

0.001%

0.001%



500.0pF

500.01pF

0.011%

0.010%



5.000nF

5.002nF

0.072%

0.071%



50.00nF

50.01nF

0.092%

0.093%



 

 

电容

介损

  1kV 

标准值

测量值

标准值

测量值



98933pF

9893pF

0

0



98933pF

9893pF

0.0101%

0.011%



98933pF

9893pF

0.0498%

0.050%



98933pF

9893pF

0.103%

0.105%



98917pF

9891pF

0.502%

0.499%



98902pF

9891pF

1.000%

1.002%



98567pF

9856pF

5.020%

4.992%



97753pF

9770pF

9.989%

9.990%



 

 

电容

介损

2kV

标准值

测量值

标准值

测量值



98933pF

9895pF

0

0



98933pF

9894pF

0.0101%

0.012%



98933pF

9895pF

0.0498%

0.051%



98933pF

9896pF

0.103%

0.102%



98917pF

9893pF

0.502%

0.499%



98902pF

9891pF

1.000%

1.001%



98567pF

9852pF

5.020%

4.999%



97753pF

9771pF

9.989%

9.980%



 

电容

介损

5kv

标准值

测量值

标准值

测量值



98933pF

9892pF

0

0



98933pF

9893pF

0.0101%

0.010%



98933pF

9894pF

0.0498%

0.051%



98933pF

9893pF

0.103%

0.102%



98917pF

9892pF

0.502%

0.505%



98902pF

9891pF

1.000%

1.001%



98567pF

9857pF

5.020%

4.998%



97753pF

9767pF

9.989%

9.991%



 

电容

介损

7.5kV

标准值

测量值

标准值

测量值



98933pF

9894pF

0

0



98933pF

9894pF

0.0101%

0.010%



98933pF

9893pF

0.0498%

0.052%



98933pF

9892pF

0.103%

0.104%



98917pF

9890pF

0.502%

0.498%



98902pF

9891pF

1.000%

1.000%



98567pF

9855pF

5.020%

4.999%



97753pF

9770pF

9.989%

9.985%



 

电容

介损

10kv

标准值

测量值

标准值

测量值



98933pF

9893pF

0

0



98933pF

9893pF

0.0101%

0.012%



98933pF

9893pF

0.0498%

0.051%



98933pF

9893pF

0.103%

0.102%



98917pF

9891pF

0.502%

0.499%



98902pF

9891pF

1.000%

1.003%



98567pF

9856pF

5.020%

4.998%



97753pF

9770pF

9.989%

9.981%



检验结论:

    本台仪器数据符合要求.  合格